34
you are viewing a single comment's thread
view the rest of the comments
[-] SoySaucePrinterInk@sh.itjust.works 5 points 11 months ago

I am referring to the small 90° gap between the flooring and the metal where you can see bits of exposed concrete. Are you saying that gap shouldn't be sealed?

[-] darkmarx@lemmy.world 10 points 11 months ago

My misunderstanding. I thought you meant from the heater to the floor.

To fix the gap you were talking about, you could do some acrylic caulking. You could do high heat silicone if you were worried about the heat, but the acrylic should be fine. Check the tube for the allowed heat range. The silicone will do vetter against the expansion and contraction, but you'd never be able to paint it. The acrylic would be paintable. But had a high chance of cracking.

[-] noride@lemm.ee 3 points 11 months ago

That's a "floating floor", looks like vinyl plank, it shouldn't be anchored to the walls. I have the exact same setup with my baseboard radiators.

[-] SoySaucePrinterInk@sh.itjust.works 2 points 11 months ago

Are you saying that I shouldn't caulk that small exposed area? I'm just wondering why since I don't know.

this post was submitted on 19 Oct 2023
34 points (100.0% liked)

Home Improvement

8895 readers
10 users here now

Home Improvement

founded 1 year ago
MODERATORS