this post was submitted on 23 Apr 2026
1 points (100.0% liked)

Ask Science

16611 readers
3 users here now

Ask a science question, get a science answer.


Community Rules


Rule 1: Be respectful and inclusive.Treat others with respect, and maintain a positive atmosphere.


Rule 2: No harassment, hate speech, bigotry, or trolling.Avoid any form of harassment, hate speech, bigotry, or offensive behavior.


Rule 3: Engage in constructive discussions.Contribute to meaningful and constructive discussions that enhance scientific understanding.


Rule 4: No AI-generated answers.Strictly prohibit the use of AI-generated answers. Providing answers generated by AI systems is not allowed and may result in a ban.


Rule 5: Follow guidelines and moderators' instructions.Adhere to community guidelines and comply with instructions given by moderators.


Rule 6: Use appropriate language and tone.Communicate using suitable language and maintain a professional and respectful tone.


Rule 7: Report violations.Report any violations of the community rules to the moderators for appropriate action.


Rule 8: Foster a continuous learning environment.Encourage a continuous learning environment where members can share knowledge and engage in scientific discussions.


Rule 9: Source required for answers.Provide credible sources for answers. Failure to include a source may result in the removal of the answer to ensure information reliability.


By adhering to these rules, we create a welcoming and informative environment where science-related questions receive accurate and credible answers. Thank you for your cooperation in making the Ask Science community a valuable resource for scientific knowledge.

We retain the discretion to modify the rules as we deem necessary.


founded 2 years ago
MODERATORS
 

First sincere apologies if this is the wrong community, I don't have lab science friends to ask about this.

Over the last few months my ph probe has been working well, then over a few days it started to drift down to reporting a ph of 2-3 instead of the 6-7 I would expect. There are so many cleaning procedures out there for ph probes, and knowing how to clean them depends on knowing what is causing them to foul.

I tried using generic probe cleaning solution, 0.1M HCL, and even just a light detergent. Nothing has worked so far.

I was reading that black spots on the ceramic could be from sulfides. And this probe is used 24/7 in my aquarium, where I dechlorinate freshly added water with a dechlorinate that I believe uses sodium thiosulfate. Could that be interacting with the probe's silver /silver chloride?

I just got thiourea and I'll be trying to prepare a thiourea/hcl solution.

What else should I try? What else might be causing this kind of fouling/errant results?