view the rest of the comments
World News
A community for discussing events around the World
Rules:
-
Rule 1: posts have the following requirements:
- Post news articles only
- Video links are NOT articles and will be removed.
- Title must match the article headline
- Not United States Internal News
- Recent (Past 30 Days)
- Screenshots/links to other social media sites (Twitter/X/Facebook/Youtube/reddit, etc.) are explicitly forbidden, as are link shorteners.
-
Rule 2: Do not copy the entire article into your post. The key points in 1-2 paragraphs is allowed (even encouraged!), but large segments of articles posted in the body will result in the post being removed. If you have to stop and think "Is this fair use?", it probably isn't. Archive links, especially the ones created on link submission, are absolutely allowed but those that avoid paywalls are not.
-
Rule 3: Opinions articles, or Articles based on misinformation/propaganda may be removed. Sources that have a Low or Very Low factual reporting rating or MBFC Credibility Rating may be removed.
-
Rule 4: Posts or comments that are homophobic, transphobic, racist, sexist, anti-religious, or ableist will be removed. “Ironic” prejudice is just prejudiced.
-
Posts and comments must abide by the lemmy.world terms of service UPDATED AS OF 10/19
-
Rule 5: Keep it civil. It's OK to say the subject of an article is behaving like a (pejorative, pejorative). It's NOT OK to say another USER is (pejorative). Strong language is fine, just not directed at other members. Engage in good-faith and with respect! This includes accusing another user of being a bot or paid actor. Trolling is uncivil and is grounds for removal and/or a community ban.
Similarly, if you see posts along these lines, do not engage. Report them, block them, and live a happier life than they do. We see too many slapfights that boil down to "Mom! He's bugging me!" and "I'm not touching you!" Going forward, slapfights will result in removed comments and temp bans to cool off.
-
Rule 6: Memes, spam, other low effort posting, reposts, misinformation, advocating violence, off-topic, trolling, offensive, regarding the moderators or meta in content may be removed at any time.
-
Rule 7: We didn't USED to need a rule about how many posts one could make in a day, then someone posted NINETEEN articles in a single day. Not comments, FULL ARTICLES. If you're posting more than say, 10 or so, consider going outside and touching grass. We reserve the right to limit over-posting so a single user does not dominate the front page.
We ask that the users report any comment or post that violate the rules, to use critical thinking when reading, posting or commenting. Users that post off-topic spam, advocate violence, have multiple comments or posts removed, weaponize reports or violate the code of conduct will be banned.
All posts and comments will be reviewed on a case-by-case basis. This means that some content that violates the rules may be allowed, while other content that does not violate the rules may be removed. The moderators retain the right to remove any content and ban users.
Lemmy World Partners
News !news@lemmy.world
Politics !politics@lemmy.world
World Politics !globalpolitics@lemmy.world
Recommendations
For Firefox users, there is media bias / propaganda / fact check plugin.
https://addons.mozilla.org/en-US/firefox/addon/media-bias-fact-check/
- Consider including the article’s mediabiasfactcheck.com/ link
New VDE recommendations say 800W on Schuko is tolerated. Wieland is of course better. That's btw not solar panel capacity but inverter capacity, you can have 2kW on your balcony as long as you're not feeding more than 800W into the net you don't need any permits no need to contact your utility no nothing.
What you should pay attention to as a renter without already existing balcony outlet though is your landlord: They generally don't like it when you drill holes through exterior walls, window frames, whatnot. Use window feed-through cables (for the PV connections, not the 220V), or dish out (quite a bit) of money to have it done properly (after talking to the landlord). At which point yes you want a Wieland outlet they're maybe 20 bucks, what's going to cost money is the electrician.
If you have an outside light on your balcony, you can probably feed it through there, though I'm not quite sure how power coming from inside the circuit interacts with the internal circuit breakers - lights sockets are usually not in the same internal subnetwork as wall sockets and this method would be feeding the power into the first circuit which is usually were all your lamps are, not into the second which is usally were all your appliances are, and it's quite possible that the circuit breakers for the lamps' circuit triggers with less current than the one for circuits meant to drive things with much higher power draw like vacuum cleaners, ovens and washing machines.
Modern meters take that into account (and you'll get one by the energy provider if you don't have it already when you tell them you installed such solar panels), everything that's used in your home gets balanced against what you produce, regardless of which specific circuit uses / provides energy. (Only immediate usage though, and if you add a battery that can save your excess energy instead of feeding it back into the grid you roughly quadruple the cost so that's quite a bit more expensive.)
I'm not thinking the main circuit breaker or the meter.
Were I live appartments have a whole board of smaller circuit breakers once for a different circuits inside the appartment - for example there might be a circuit just for illumination, another for kitchen wall plugs, a different for bedroom wall plugs and so on, and for each of these there will be one such small circuit breaker.
These small circuit breakers normally have a lower trigger point than the main circuit breaker, though they might be different depending on the circuit since different kinds of things draw different amounts of power - i.e. household lamps aren't going to be drawing 1000W whilst an electric oven or electric heater might very draw that or more power.
In a normal situation, the current comes from the outside, through the meter and the main circuit breaker and then gets divided based on demand and goes through each smaller circuit breaker and feeds whatever is drawing power in those circuits.
If you have a balcony plug-in solar power system there, wired to any circuit, IF the power does come OUT from that circuit (I'm not sure, though it makes sense it can) and into the other circuits, then wouldn't the trigger point of the circuit breaker for that circuit (which as I said is lower than the main circuit breaker's) be important?
If I remember it correctly circuit breakers are electromechanic and don't really care which direction the current is going (so OUT or IN is all the same) just how much of it is passing through, so the current going OUT instead of IN on one of those circuit breakers would be fine, but even that being the case, it might still be a problem to wire the solar power via the circuit for the illumination rather than the circuit for the wall socked because the circuit breaker for the illumination circuit might have a lower trigger point than that for the wall sockets circuit (because you might connect a 1000W device to a wall socket whilst a 1000W lamp was already insanelly powerful back in the Filament Lamp days and is much more so in the LED Lamp days).
PS: Your point about "will power come out of my household and how does that interact with the meter and the main circuit breaker" is also important, but I wasn't even thinking about that since I was thinking about just the difference between wiring the power out from an appartment balcony via the circuit for the outside lighting vs bringing that power inside the dwelling and connecting it to a wall socket and hence a different circuit.
I only know 16 amp breakers (~3600 W), not sure if lower current circuits are commonly used in Germany. In my experience every socket can power devices like a toaster or lawn mower, so they're all suitable for such solar inverters.
Lighting fixtures in adjacent rooms are supposed to be on different breakers, not sure whether that also applies to balconies, not a room as such is it... but I'm no electrician. While I did get an A in electrotechnics I don't know the VDE norms by heart (nor would I touch the wiring in a breaker panel).
OTOH it's perfectly permissible to have outlets and lighting on the same breaker. That's all to say I wouldn't be surprised or shocked to find that a balcony light is on a general "living room" circuit.
I don't think it matters in practice which phase the inverter is on. If you run the meter backwards with one phase and forwards with another, it should be still. We're not talking about an autonomous installation, after all, when the external network is down and there's no frequency to sync to those inverters stop outputting.
Which all makes me wonder: Why aren't we mandating that all new installations come with network isolation and points where you can plug in panels, battery etc? The hardware isn't that expensive and installing it is practically free when you're doing the initial installation.