United Kingdom
General community for news/discussion in the UK.
Less serious posts should go in !casualuk@feddit.uk or !andfinally@feddit.uk
More serious politics should go in !uk_politics@feddit.uk.
Try not to spam the same link to multiple feddit.uk communities.
Pick the most appropriate, and put it there.
Posts should be related to UK-centric news, and should be either a link to a reputable source, or a text post on this community.
Opinion pieces are also allowed, provided they are not misleading/misrepresented/drivel, and have proper sources.
If you think "reputable news source" needs some definition, by all means start a meta thread.
Posts should be manually submitted, not by bot. Link titles should not be editorialised.
Disappointing comments will generally be left to fester in ratio, outright horrible comments will be removed.
Message the mods if you feel something really should be removed, or if a user seems to have a pattern of awful comments.
view the rest of the comments
Any Germans here? I heard balcony solar (that you just plug in an outgoing socket) is everywhere in Germany.
Germany doesn't use ring mains wiring and their housing stock is considerably more modern than the UK's. So they have more reliable insulation and more modern breaker systems.
That's not to say it's not possible here. It is. It's just the UK needs to take a more cautious approach because we have a greater risk of safety issues due to the way our homes are wired and the overall greater age of components.
All this to say, I hope for the roll out soon, but comparing our situation to Germany doesn't help much because our situation is more complex and will likely involve sparkies in a greater way than Germany needs to. Modern homes or those with up to date circuitry may be fine, but Victorian/Georgian homes will likely need somebody to give the place a look over first.
I see this argument a lot, but are you sure? Let's assume the cables are using 2.5mm^2 which is around 1950's installation "standards", in the worst case that's 13A derated. Is that not enough for 800W of power? Now, I'm not saying that a standard 3-pin plug couldn't cause fire issues, or a bad connection, but that's true for any 3-pin plug with an 800W load. And this completely bypasses the RCD issue because even 800*2 W would still not be enough to cause any fire issues.
I'd be more worried about the plug being used, rather than the current situation.
Don't take my word for it. This is what the Institution of Engineering and Technology has to say:
https://www.theiet.org/media/press-releases/press-releases-2026/press-releases-2026-january-march/24-march-2026-iet-urges-households-to-check-electrical-safety-before-using-plug-in-solar-products
That's kind of wild, a bit like when we redid our wiring in our -58 apartment, it was similar, two "legs" and you just grounded from it through an appliance, apparently... One leg for the kitchen, one for the rest of the rooms...
Now it's like one leg for every thing(+ loads of breakers), like the fridge has its own cable and so on. I wonder how that works if you inject electricity into one of them...