this post was submitted on 01 Jul 2026
1053 points (98.2% liked)

Technology

86105 readers
3550 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 3 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] BCsven@lemmy.ca 3 points 4 days ago (1 children)

Apparently for an average data center youd need bewtwen 100,000 to 500,000 meters squared of radiator area

[–] NotMyOldRedditName@lemmy.world -2 points 4 days ago* (last edited 4 days ago) (1 children)

These dishes only need a radiator < 2 times the size of the ISS radiators if they were using the radiators on the ISS. They're only 125kw avg, 150kw peak and the ISS radiators are rated 84kw.

I'm sure there's been advancements in radiating heat efficiently in space as well.

Cumulatively it'll be a lot, but the solar panels will be even more. They're way bigger than the radiators.

[–] BCsven@lemmy.ca 4 points 4 days ago (1 children)

A dara center is more than 100Kw.

[–] NotMyOldRedditName@lemmy.world -1 points 4 days ago* (last edited 4 days ago) (1 children)

You're right, its going to be 10s of thousands of these smaller 125kW avg dishes, but they only need to solve the problem at the scale of 150kw peak.

[–] Krauerking@lemy.lol 1 points 4 days ago (1 children)

We can't fit tens of thousands of massive radiators floating around up there. The ISS has 27.2 meters / 88 feet of ammonia filled radiators that is able to expend... 56kW of heat.

Your 125 average is 2 and quarter times more that the ISS loop meaning we would need to launch up with each shitty satellite an additional 73 meters / 235 feet of trusses, support beams, gold and copper paneling and ammonia filled loops for each individual satellite.

Oh right and you want tens of thousands so at a reasonable 20,000 of those we need 1,500KM of radiators alone which is the radius of the fucking moon.

No, it won't be that, cause its just as dumb and unfeasible.

[–] NotMyOldRedditName@lemmy.world 0 points 3 days ago* (last edited 3 days ago) (1 children)

The ISS is rated for 84kw and runs substantially cooler, they wont actually be that big. They will be smaller than the ISS whatever they end up being.

The temperature of the radiators scale to the 4th power.

It was more of a, it this is the worst case limit.

Edit: meant to say smaller than 2x which is the upper limit i said above.

[–] Krauerking@lemy.lol 1 points 3 days ago (1 children)

The radiators are rated at 14kw a pair. There is other cooling mechanisms that are used and you are using the combined total. This scale and resource requirements become quickly ridiculous for launching that many radiator arrays alone.

Your math is all over the place. And this isnt any kind of scientific.

[–] NotMyOldRedditName@lemmy.world 1 points 3 days ago* (last edited 3 days ago) (1 children)

Straight from NASA

the EATCS is designed to provide 35 kW of heat rejection per loop for a total capability of 70 kW

https://www.nasa.gov/wp-content/uploads/2021/02/473486main_iss_atcs_overview.pdf

And raising the temperature factually increase the radiators capability to the 4th power, and the ISS runs at a cooler temperature than these GPUs need to run at, thus these radiators will be smaller. (edit: NASA source For a given amount of waste heat, the lower the rejection temperature, the larger the required radiating surface. For radiation heat transfer, the quantity of heat rejected is proportional to the fourth power of temperature; therefore, the area requirements increase rapidly as the temperature decreases. T)

I've been pretty consistent in this entire post on the 70kW but max rated for 84kW, but i might have been wrong about the 84 part mixing that up with something else.

I've been consistent with the AI datacenter being - 125kw avg, 150kw peak as well. 2x ISS before accounting for temperature difference is 140kW which is < 2x average, but not quite peak which is 2.15x.

There is no way these will be bigger than 2x what the ISS has.

Edit: e.g post saying 84 & 70

https://lemmy.world/post/48895224/24572272

https://lemmy.world/post/48895224/24559267

Edit: Looks like you were working off of older data

the EATCS provides a substantial upgrade in heat rejection capacity from the 14kW capability of the Early External Active Thermal Control System (EEATCS).

[–] Krauerking@lemy.lol 2 points 3 days ago

Thank you for the update on the EATCS system.