[-] A_Random_Idiot@lemmy.world 25 points 2 months ago

as someone who has strung a ton of lights the wrong way around on more than one occasion... I can understand the desire for some magic solution that doesnt require undoing and redoing your work..

but fuck, You don't mess around with electricity.

People also make these stupid suicide cables to plug generators into houses during disasters, often backfeeding power into the lines that may be down and can cause serious injury to workers trying to restore power.

[-] Lizardking27@lemmy.world 13 points 2 months ago

FYI, you can just turn off the main breaker of the residence to prevent backfeeding into the power lines.

[-] RegalPotoo@lemmy.world 8 points 2 months ago

You can, but if forgetting to flip a switch can result in death, then you need a stronger safety control

[-] Lizardking27@lemmy.world 1 points 2 months ago

Someone incompetent enough to forget to shut off the main shouldn't be operating a generator anyway.

[-] RegalPotoo@lemmy.world 3 points 2 months ago

That's not the point. Normal, sensible people make mistakes because they are tired or stressed or got distracted or just plain unlucky, so things have to be designed so that people can make a mistake and it not instantly create a potentially lethal situation

[-] Lizardking27@lemmy.world -3 points 2 months ago* (last edited 2 months ago)

I don't think you completely understand what's being discussed here.

[-] SpaceCowboy@lemmy.ca 1 points 2 months ago

Someone who's not competent enough to install a proper transfer switch (or at least hire a professional to do it) shouldn’t be operating a generator.

[-] brianorca@lemmy.world 5 points 2 months ago

If someone can't make the own cord, what's the chance they know how vital it is to flip the breaker?

[-] MystikIncarnate@lemmy.ca 0 points 2 months ago

.... Except the breaker only interrupts the connection on the "hot" line....

[-] RegalPotoo@lemmy.world 10 points 2 months ago

Yeah, there is a reason why proper installations require actual transfer switches or at least a manual interlock to prevent both feeds being connected at the same time. I'm also not sure what would happen if your generator was out of phase with the grid when it reenergised, but I'm sure it wouldn't be good

[-] A7thStone@lemmy.world 6 points 2 months ago

If your generator was connected to mains when they came back on it would probably just kill your generator. It is the least robust device in the chain. The next step is blowing up the transformer on the pole which is a spectacular light show. It is also very expensive, and will piss off your entire neighborhood who were just about to get power back and now have to wait for the power company to fix the transformer you blew up by being a dumb ass. Finally it is possible that you would trip out the switch yard which is going to make even more people angry. The biggest risk is you putting power back on the lines that people are working on. That transformer on the pole works both directions. It drops the usual 13.8kV on your local power lines to the 240/120V in your house. It will also turn the 120/240 from your generator into 13.8 on the lines that are being worked on. 13.8 will kill you before you even know you touched it. That is why line workers go through multiple tests before they get near lines they are working on. They will notice there is power on lines that are supposed to be dead. They will find where that power is coming from. They will fine you lots of money. There may be criminal charges.

this post was submitted on 24 Aug 2024
954 points (99.2% liked)

Lemmy Shitpost

26707 readers
2744 users here now

Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.

Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means:

-No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...

If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.


Also check out:

Partnered Communities:

1.Memes

2.Lemmy Review

3.Mildly Infuriating

4.Lemmy Be Wholesome

5.No Stupid Questions

6.You Should Know

7.Comedy Heaven

8.Credible Defense

9.Ten Forward

10.LinuxMemes (Linux themed memes)


Reach out to

All communities included on the sidebar are to be made in compliance with the instance rules. Striker

founded 1 year ago
MODERATORS