Microwave on a dedicated circuit above counter in kitchens and gfci protected per code
You're not putting a space heater on your kitchen counter
And once again youre supplying up to 1200w, not drawing 1200w. Any power supply system will just be matching the load being drawn
I really dont think this is the degree of a problem you think it is
No there is a real concern there. Suppose you have a daisy chain that goes breaker - PV panel - load. Say you have 20A draw on the load - enough to trip a 15A breaker, but the PV is providing 10A. In that case you only have 10A at the breaker, but your wires will be significantly over-current.
I think the issue is that, if you have a circuit designed and protected for X, then put Y solar in, you can get a situation where X+Y is flowing down some of the wires. It's more than they are rated for, but the breaker doesn't see it.
What matters is the differential. A breaker limits the input. E.g. to 16A. A plug in solar provides an independent input. E.g. 10A. Under certain circumstances, multiple loads, up to 26A total could exist on the spur, without the breaker being triggered. This could put up to 26A down some of the wiring of the spur.