954
Cords (slrpnk.net)
you are viewing a single comment's thread
view the rest of the comments
[-] yesman@lemmy.world 13 points 3 months ago

I don't really get it. Sure, the exposed prongs would be energized once you plugged one side in, but if you plugged the other side into a second outlet (assuming you didn't cross live/neutral), nothing would happen. (those two outlets were likely tied together anyway)

[-] mipadaitu@lemmy.world 28 points 3 months ago

You don't work around dangerous things assuming you'll never make a mistake, you work around dangerous things assuming you'll never make three mistakes at the same time.

You are not immune to making one (or more) mistakes, no matter how careful you think you are.

[-] BaumGeist@lemmy.ml 5 points 3 months ago

Correction: you don't work around dangerous things assuming you'll make a mistake long

[-] Foofighter@discuss.tchncs.de 19 points 3 months ago

Well, maybe it's because you may die if you accidentally touched touched the prongs? The purpose of female plugs is among other reasons to prevent accidentally touching them.

[-] QuizzaciousOtter@lemm.ee 8 points 3 months ago* (last edited 3 months ago)

I guess the fact that it can kill you easily is not enough to call it a suicide cable lmao

[-] dufkm@lemmy.world 5 points 3 months ago

Yeah, let's call it a self defence cable instead. Like a corded taser.

[-] ayyy@sh.itjust.works 15 points 3 months ago

In addition to the exposed prongs, it also means you are passing current into a circuit of unknown capacity without using a safety breaker. You may also be back feeding into your neighborhood power grid and can kill people in the street/other houses that were not expecting the lines to be energized.

[-] Metype@lemmy.world 15 points 3 months ago* (last edited 3 months ago)

The problem really is the super exposed hot prong you now have once you plug one end in

[-] Revan343@lemmy.ca 14 points 3 months ago* (last edited 3 months ago)

50-50 chance whether those two outlets are on the same phase or opposite phases; if it's the latter, congrats, that's a 240V short.

Besides, if there's an outlet at the far end of your string of lights, you don't need this, you just plug it in there

[-] brianorca@lemmy.world 5 points 3 months ago

Two things: 1: there's a high chance you do cross live and neutral, or even live and live on different phases. 2: using it to plug in a generator to power your house can kill electrical workers who are trying to restore a power outage. (If you fail to open your circuit breaker.)

[-] Davidchan@lemmynsfw.com 2 points 3 months ago

Double live is very bad and the cord becomes a literal short. If you're lucky a breaker will flip or fuse burn out. If you're not so lucky you have a cable thats either going to start a fire burning its insulation off and melting itself, or potentially exploding depending on quality and type of cable.

[-] Duamerthrax@lemmy.world 1 points 3 months ago

Why would you "need" one of these if you could plug in the other end into a second outlet? The point is that idiots don't plan out their christmas light layout and end up with the wrong end at the outlet. They decide that they would rather drive to the hardware store and buy/build a suicide cable rather then just taking the lights down and rehanging them or running an extension cord to where the male end of the lights are.

this post was submitted on 24 Aug 2024
954 points (99.2% liked)

Lemmy Shitpost

27073 readers
6046 users here now

Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.

Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means:

-No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...

If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.


Also check out:

Partnered Communities:

1.Memes

2.Lemmy Review

3.Mildly Infuriating

4.Lemmy Be Wholesome

5.No Stupid Questions

6.You Should Know

7.Comedy Heaven

8.Credible Defense

9.Ten Forward

10.LinuxMemes (Linux themed memes)


Reach out to

All communities included on the sidebar are to be made in compliance with the instance rules. Striker

founded 2 years ago
MODERATORS